The CHP-FCP-1000 is a PEM Fuel Cell Power System intended for industrial applications, Power-2-Power purposes for solar fields and wind farms and for co-generation applications in the built environment. The CHP-FCPS-1000 is optimized for seamless integration in local or collective electricity grids by being able to use all sorts of commercial off-the-shelf power electronics. The PemGen Fuel Cell Power System portfolio is available on a configure-to-order basis. Get in touch to tune this system for your specific application.
General | Fuel Cell Type | Low Temperature Proton Exchange Membrane (LT-PEM) |
Fuel Cell Model | 120x Nedstack FCS 13-XXL | |
ELECTRICAL | Nominal Power | 1000 kWe |
Peak Power (BoL) | 1252 kWe | |
Voltage range | 500 - 1000 VDC | |
Current range | 0 - 2400 A | |
ENCLOSURE | Weigth | 29000 kg |
Built Level | 40 ft ISO Container (High Cube) | |
Length | 12.19 m | |
Width | 2.44 m | |
Height | 2.90 m | |
IP-rating | IP 54 | |
HYDROGEN FEED | Quality | Grade ≥ 2.5 (CO < 0.2 ppm) |
Supply pressure | 0.3 – 6 barg | |
Nominal consumption | 59 kg/MWhe | |
Max consumption | 80 kg/h | |
COOLANT | Medium | DI water or BASF FC G20 |
Outlet Temperature | Max 65 °C | |
Required Cooling Capacity | 1800 KWth | |
Recoverable heat | >800 kWth | |
AMBIENT CONDITIONS | Operating Temperature | -5 – 40°C |
Storage Temperture | 5 – 60°C (optional -20°C – 60°C) | |
APPLICATION | Intended use | Residential Blocks |
Commercial and institutional facilities | ||
Chemical sites | ||
Placement | To be placed on flat concrete surface or steelframe | |
LIFESPAN | Balance of Plant | 20 years |
Stack Refurbishment | 24k - 30k running hours | |
COMPLIANCY | Standards | IEC-62282-2 |
IEC-62282-3 | ||
2006/95/EC | ||
2006/42/EC | ||
2004/108/EC |
Downloads