The Generation 3 is a modular hydrogen fuel cell system, producing electricity and heat only emitting water. It‘s unique design separates the fuel cell module from the air supply, enabling easier integration and optimal operation. This next step in the PEMFC systems, enhances efficiency and accelerates sustainability in power generation.
Performance
| Peak Power Beginning of Life |
1000 kW |
| Prime Power |
900 kW |
| Nominal Power |
700 kW |
| Ramp Up Time |
20 %/s |
| Start Up Time |
<60 s |
| Voltage Output |
800 VDC |
| Current Output |
2 x 765 A |
Environment
| Air Supply |
Ambient |
| Height (Altitude) |
max 2000 m |
| Water Production (100% load) |
~300 kg/h |
| Operating Temperature |
-25ºC to 45 ºC |
| Storage Temperature |
-45ºC to 55 ºC |
| Process Air |
935 Nm3/h |
| Ventilation |
500 Nm3/h |
Cooling
| Maximum heat generation (EoL) |
1200 kWt |
| Maximum Supply Temperature |
≤ 35 ºC |
| Maximum Return Temperature |
55 ºC |
Efficiency and hydrogen consumption
| Net Output |
|
Beginning of Life |
|
End of Life |
|
| 110% load |
1000 kW |
49.5% |
60.0 kg/h |
- |
- |
| 100% load |
900 kW |
50.3% |
53.1 kg/h |
43.9% |
60.8 kg/h |
| 80% load |
700 kW |
51.9% |
47.5 kg/h |
45.6% |
45.5 kg/h |
| 50% load |
450 kW |
53.7% |
40.0 kg/h |
47.5% |
28.2 kg/h |
| 25% load |
225 kW |
51.9% |
12.4 kg/h |
48.4% |
13.8 kg/h |
| 5% load |
50 kW |
48.0% |
3.2 kg/h |
48.0% |
3.2 kg/h |
Compliancy
| Inlet pressure |
≥ 2 bar |
| Hydrogen Standards |
Type I, Grade E, Category 3 (ISO 14687-2) |
| Standards |
IEC-62282-3 |
| Maritime Approval (in progress) |
Bureau Veritas, RINA |